Remote Engineering Support – CAD/BIM, Low Voltage & Fire Alarm Systems

Please login or register as jobseeker to apply for this job.

TYPE OF WORK

Full Time

SALARY

$4 to $5 per Hour

HOURS PER WEEK

40

DATE UPDATED

Oct 17, 2026

JOB OVERVIEW

About Us
Industrial Electronic Systems, Inc. (IES) is a U.S.-based fire alarm and life safety systems company serving commercial customers in Northern California. We specialize in fire alarm design, installation, inspections, and low voltage systems integration.

About the Role
We are hiring a Remote Engineering Support specialist to help our U.S. engineering team design and document low voltage and fire alarm systems for commercial buildings. This is a hands-on engineering role — you'll model in BIM, draft in CAD, research code, and produce real deliverables for active construction projects.

We need someone who is:
• A strong CAD and BIM modeler (this is non-negotiable)
• Experienced with low voltage system design
• Comfortable with NFPA 72 / NEC code research (fire alarm experience is a big plus)
• A self-starter who can solve design challenges independently
• Detail-obsessed — drawings, layers, sheet sets, and revisions all done right
________________________________________
Key Responsibilities

CAD & BIM Engineering
• Produce 2D AutoCAD drawings — device layouts, risers, wiring diagrams, system details, and submittal sets.
• Build and maintain 3D BIM models (Revit / Navisworks) for low voltage and fire alarm systems.
• Set up sheets, viewports, title blocks, layers, and XREFs to company CAD standards.
• Coordinate clash detection and drawing updates with the broader project model.

Low Voltage & Fire Alarm Design Support
• Assist in designing NFPA-compliant fire alarm systems (device layout, spacing, placement).
• Support design of access control, intrusion, structured cabling, and other low voltage systems.
• Identify code-driven requirements — smoke/heat detector spacing, notification coverage, strobe candela placement, circuit routing and survivability.
• Review architectural and electrical drawings for design impact and coordination.

Research & Problem Solving
• Look up AHJ requirements (city/state fire department standards).
• Compare NFPA 72 / NEC requirements against local code amendments.
• Document findings and communicate design impacts to U.S. engineers.
• Identify missing information in plans and propose solutions before they become RFIs.

Submittals & Closeout
• Create submittal drawings, cut sheets, and product data packages.
• Update as-built drawings from field markups.
• Maintain version control and clean project files throughout the job lifecycle.
________________________________________
Required Qualifications
• Strong AutoCAD 2D skills (layers, XREFs, sheet sets, scaling) — required.
• Strong BIM skills in Revit and/or Navisworks — required.
• Solid understanding of low voltage systems (fire alarm, access control, security, structured cabling).
• Fire alarm experience is a big plus — NFPA 72, NEC, AHJ familiarity preferred.
• Ability to read and interpret architectural, mechanical, and electrical plans.
• Strong analytical skills and willingness to research code/AHJ requirements.
• Excellent written and spoken English.
• Reliable workstation, stable internet, and willingness to overlap with U.S. Pacific Time.

VIEW OTHER JOB POSTS FROM:
SHARE THIS POST
facebook linkedin
  BENCHMARKS  
Loading Time: Base Classes  0.0010
Controller Execution Time ( Jobseekers / Job )  0.0281
Total Execution Time  0.0299
  GET DATA  
No GET data exists
  MEMORY USAGE  
1,501,128 bytes
  POST DATA  
No POST data exists
  URI STRING  
jobseekers/job/Remote-Engineering-Support-CADBIM-Low-Voltage-Fire-Alarm-Systems-1751404
  CLASS/METHOD  
jobseekers/job
  DATABASE:  onlinejobs (Jobseekers:$db)   QUERIES: 13 (0.0129 seconds)  (Hide)
0.0003   SELECT *
                                
FROM exrates
                                WHERE rate_name 
= 'USD-PHP' 
0.0004   SELECT *
FROM `employer_jobs`
WHERE `job_id` = 1751404
 LIMIT 1 
0.0012   SELECT *
FROM `employers`
WHERE `employer_id` = 528020
 LIMIT 1 
0.0017   SELECT COUNT(*) AS `numrows`
FROM `t_thread` `t`
LEFT JOIN `t_thread_misc` `misc` ON `t`.`id` = `misc`.`thread_id`
WHERE `t`.`job_id` = 1751404
AND `misc`.`id` IS NULL 
0.0005   SELECT e.business_name, e.logo, e.website, e.rebill_date, e.date_added member_date, hits, DATEDIFF('2026-10-18',ej.date_added) duration_days, DATEDIFF('2026-10-18',e.rebill_date) duration_rebill, ej.*, e.deactivate FROM employers e, employer_jobs ej WHERE e.employer_id = ej.employer_id AND
                                   ((
e.user_level >= '500' AND ej.date_added <= e.rebill_date)
                                   OR 
e.employer_id = '' OR (ej.date_approved <> '2000-01-01' and DATEDIFF('2026-10-18',ej.date_added) <= 14 ))
                                   AND 
e.deactivate != 1 AND ej.deleted = 0 AND job_id = '1751404' 
0.0003   SELECT *
FROM `employer_jobs_skills` `ejs`
LEFT JOIN `skills_categories` `sc` ON `ejs`.`skill_id` = `sc`.`id`
WHERE `job_id` = 1751404 
0.0009   UPDATE employer_jobs SET hit_counts = '***Oct-17-2026=936***Oct-18-2026=4' WHERE job_id= '1751404'  
0.0006   UPDATE employer_jobs SET monthly_hits = '***Oct-2026=940' WHERE job_id= '1751404'  
0.0003   SELECT date_sent FROM jobseeker_sent_emails WHERE jobseeker_id = '' AND job_id = '1751404' AND status LIKE 'sent%' ORDER BY id DESC  
0.0003   SELECT *
FROM `employer_jobs_skills` `ejs`
LEFT JOIN `skills_categories` `sc` ON `ejs`.`skill_id` = `sc`.`id`
WHERE `job_id` = 1751404 
0.0056   SELECT COUNT(*) AS `numrows`
FROM `employer_jobs`
WHERE `employer_id` = '528020'
AND `date_added` >= '2022-06-08' 
0.0004   select * from teasers 
0.0003   SELECT * FROM skill_categories WHERE skill_cat_id='' 
  HTTP HEADERS  (Show)
  SESSION DATA  (Show)
  CONFIG VARIABLES  (Show)